Most tank suppliers stop at the shell-to-roof weld. Zhongneng Huajian (Shandong) Metal Structure Co., Ltd.-internationally ZN Metal Structure-treats the tank roof as a structural system, not a lid. That matters when the roof must span 40 m without internal columns, carry solar panel racks, maintenance cranes or pipe bridges, and still keep the tank shell within API 650 allowable compression at the eave.
Space frame is the missing link in many tank farms
A 66 m diameter desalination auxiliary water tank in Dammam does not need a space frame. But the pump house beside it, the chlorine dosing building, the dry bulk additive shed and the truck loading canopy all do. ZN's 15,000 m² Shandong base runs both: cylindrical tank shells on the rolling line, and bolted spherical-node space frames in the structural bay. The advantage is coordination-one drawing register, one weld map philosophy, one coating specification language.
What ZN space-frame jobs typically include
Hollow-section chord and bracing members, Q355B / ASTM A500 Gr.B
Forged or cast spherical nodes, CNC drilled end plates, M24–M36 hi-strength bolts
Roof cladding in colorbond, aluminum trapezoidal sheet or translucent FRP panel
Suspended walkway and LED light truss hung from main grid, not from tank shell
Lightning down-conductor routed independently of tank grounding to avoid induced arcs

Why tank engineers should care
If a contractor hangs a 12-ton pipe bridge from a fixed cone roof that was only designed for 1.2 kPa live load, the compression ring buckles. ZN's integrated approach puts the pipe bridge on the space frame, and the tank roof only carries weather load. For airport fuel depot projects, the same space-frame crew builds the loading canopy while the tank crew erects the 5,000 m³ Jet A-1 tank-different steel, same project manager.
Case pattern (generic, site-verified style)
A North African desalination EPC asked for: 2 × 66 m water tanks + pump hall 36 m × 60 m clear span + chemical storage building. ZN delivered tank shells to API 650 / EN 14015, pump hall as bolted space frame to EN 1090-2, chemical building as welded portal frame. Single MDR package, single HSE plan, single spare-bolt kit. The owner saved 3 weeks of interface meetings because the tank and roof teams were not pointing at each other.
FAQ snippet
"Can a storage tank roof be a space frame?" For atmospheric vertical tanks, the standard answer is cone/dome/IFR. But adjacent buildings, canopies and large pump houses on the same plot can use space frames supplied by the same vendor-this reduces structural interface risk.
ZN's structural licenses (Class II Steel Structure Specialty Contracting) let it sign off both the tank-adjacent frame and the tank roof platform in one EPC wrapper.